IMPORTANT This Loadcell must be mounted in accordance with Elphinstone Instructions. Failure to do so may void warranty. Specifications to change without notice. These specifications supercede all previous specifications as of October 2006.
Key
226 mm
78 mm
60 mm
83 mm
83 mm
M12 x 1.75 x 25mm Deep
30 mm
Connections
Excitation +
Signal +
Signal -
Excitation -
Mounting Requirements
Top Plate must be dead stiff and machined flat after welding
Bottom Mounting must be dead stiff
Bearing plate must be welded using 10mm fillet
Across end and fully down each side
Precautions
Do not strike an Arc on the loadcell body with a welder
It is Ok to use the loadcell to position the Bearing plate for tack welding only
Remove the loadcell to complete welding procedure
Do not damage the bottom cover plate as this protects delicate strain gauges
Take care to protect the loadcell connector/cable as this can not be replaced in the field
Fit protection for the loadcell connector from stones and foreign objects which may damage it
Do not damage or paint over the Part/Serial Number identification tag
If you have any enquiries about the products you've seen on this page, please do not hesitate to get in touch with us at any time for more information.